製品
製品の詳細
> 製品 >
8.2-12.4GHz WR-90 WAVEGUIDE LOAD

8.2-12.4GHz WR-90 WAVEGUIDE LOAD

MOQ: 5個
価格: negotiable
支払方法: L/C、D/A、D/P、T/T
供給能力: 500
詳細情報
起源の場所
中国
ブランド名
Vinncom
証明
ISO 9000 ROHS
モデル番号
VN-WGLD-0812-WR90
部品番号:
VN-WGLD-0812-WR90
動作周波数(GHz):
8.2~12.4
阻力 (オム):
50
VSWR:
≤1.03
インタフェース:
WR137(BJ70)
製品の説明

 

8.2-12.4GHz WR-137 WAVEGUIDE LOAD

 

  • Broadband operation
  • Low VSWR (Voltage Standing Wave Ratio)
  • Protection of sensitive transmitter components

WAVEGUIDE LOAD is not an option – it is a mandatory component in any non‑radiating waveguide setup. Always verify the power rating, flange type, and cooling method before deploying a WAVEGUIDE LOAD in your system.

A WAVEGUIDE LOAD is a passive, non-radiating termination device used in waveguide transmission systems. Its primary electrical characteristic is to present a matched impedance (typically 50 ohms equivalent or the waveguide’s characteristic impedance) to the source, thereby absorbing incident microwave energy with minimal reflection.

oupler port. Ensure the flange type (e.g., UG, CPR, cover, choke) matches the system.

 

                             VN-WGLD-0812-WR90.pdf

Part Number VN-WGLD-0812-WR90
Operating Frequency ( GHz ) 8.2-12.4
Impedance ( Ohm ) 50
VSWR ≤1.03
Operating Temperature ( ℃ ) -40 ~ + 80
Interface WR90(BJ100)
Dimension(mm) As below
Handling Power 2 (Watt, max)
ROHS Compliance Yes
 
 
 
                                               8.2-12.4GHz  WR-90  WAVEGUIDE LOAD 08.2-12.4GHz  WR-90  WAVEGUIDE LOAD 1
 

推奨する製品
製品
製品の詳細
8.2-12.4GHz WR-90 WAVEGUIDE LOAD
MOQ: 5個
価格: negotiable
支払方法: L/C、D/A、D/P、T/T
供給能力: 500
詳細情報
起源の場所
中国
ブランド名
Vinncom
証明
ISO 9000 ROHS
モデル番号
VN-WGLD-0812-WR90
部品番号:
VN-WGLD-0812-WR90
動作周波数(GHz):
8.2~12.4
阻力 (オム):
50
VSWR:
≤1.03
インタフェース:
WR137(BJ70)
最小注文数量:
5個
価格:
negotiable
支払条件:
L/C、D/A、D/P、T/T
供給の能力:
500
製品の説明

 

8.2-12.4GHz WR-137 WAVEGUIDE LOAD

 

  • Broadband operation
  • Low VSWR (Voltage Standing Wave Ratio)
  • Protection of sensitive transmitter components

WAVEGUIDE LOAD is not an option – it is a mandatory component in any non‑radiating waveguide setup. Always verify the power rating, flange type, and cooling method before deploying a WAVEGUIDE LOAD in your system.

A WAVEGUIDE LOAD is a passive, non-radiating termination device used in waveguide transmission systems. Its primary electrical characteristic is to present a matched impedance (typically 50 ohms equivalent or the waveguide’s characteristic impedance) to the source, thereby absorbing incident microwave energy with minimal reflection.

oupler port. Ensure the flange type (e.g., UG, CPR, cover, choke) matches the system.

 

                             VN-WGLD-0812-WR90.pdf

Part Number VN-WGLD-0812-WR90
Operating Frequency ( GHz ) 8.2-12.4
Impedance ( Ohm ) 50
VSWR ≤1.03
Operating Temperature ( ℃ ) -40 ~ + 80
Interface WR90(BJ100)
Dimension(mm) As below
Handling Power 2 (Watt, max)
ROHS Compliance Yes
 
 
 